Provide enough information to allow the selection of the manufacturer product to meet requirements. This information may also be used to replace the installed product during the operation stage of the building's lifecycle. Information covering the execution of the deliverable should also be provided in the associated specification.
Name |
Definition |
|
Manufacturer |
An example value being System manufacturer. |
|
Standards |
An example value being To BS EN 60839-11-1 and BS EN 60839-11-2. |
|
Format |
An example value being Microprocessor based. |
|
Security grading |
An example value being To BS EN 60839-11-1, Grade 1. |
|
Environmental classification |
An example value being To BS EN 60839-11-1, Class I. |
|
Enclosure - Material and finish |
An example value being Plastic. |
|
Synchronize date and time |
An example value being Once a day. |
|
Synchronize date and time - Colour |
An example value being Black. |
|
Rated operational voltage (Ue) |
An example value being 240 V a.c. |
|
Rated operational current (In) |
The Rated operational current (In) of the Access control units. |
|
Battery backup - Battery location |
An example value being Internal to controller. |
|
Battery backup - Battery backup capacity |
An example value being Two hours. |
|
Type of operation |
An example value being Networked. |
|
Number of doors per controller |
An example value being One. |
|
Number of users (minimum) |
An example value being 300. |
|
Communication interface |
An example value being Ethernet. |
|
Visual indication |
An example value being LCD text panel. |
|
Interfaces - Door lock relays |
An example value being One. |
|
Interfaces - Door status monitoring |
An example value being One. |
|
Interfaces - Readers |
An example value being One. |
|
Interfaces - Volt free relays |
An example value being One. |
|
Interfaces - Request to exit buttons |
An example value being One. |
|
Data encryption |
An example value being 128 bit. |
|
Random access memory (RAM) capacity (minimum) |
An example value being 256 MB. |
|
Storage memory capacity |
An example value being 256 MB Flash memory. |
|
Administration access |
An example value being Password protected. |
|
Database |
An example value being ODBC compatible. |
|
Information fields per user |
An example value being Access period. |
|
Spare information fields per user (minimum) |
An example value being 10. |
|
Import and export of database in ASCII format |
An example value being Required. |
|
Incorporation of external data |
An example value being Incorporate site layouts into system graphics. |
|
Integral event memory capacity (minimum) |
An example value being 2000. |
|
Monitor and record the following transactions and events |
An example value being Forced access. |
|
Events and transactions |
An example value being Data and time stamp. |
|
Customised event alarms |
An example value being Display. |
|
Control features - Include the following |
An example value being Access point status monitoring. |
|
Control features - Anti-passback |
An example value being Global. |
|
Control features - Time between credential presentation and door unlock (maximum) |
An example value being 0.3 seconds. |
|
Reports - Transaction and event reports |
An example value being By access point.By area.By department.By time and date period.By transaction type.By user. |
|
Reports - Other reports |
An example value being Building occupancy.Staff time and attendance. |
|
Publishing |
An example value being Export to pdf. |
|
Accessories |