Provide enough information to allow the selection of the manufacturer product to meet requirements. This information may also be used to replace the installed product during the operation stage of the building's lifecycle. Information covering the execution of the deliverable should also be provided in the associated specification.
Name |
Definition |
|
Manufacturer |
The Manufacturer of the Glazed enclosures. |
|
Performance criteria |
The Performance criteria of the Glazed enclosures. |
|
Style |
An example value being Edwardian. |
|
Roof - Performance criteria |
The Roof - Performance criteria of the Glazed enclosures. |
|
Roof - Frame - Material |
An example value being Aluminium. |
|
Roof - Frame - Thermal break |
An example value being Required. |
|
Roof - Frame - Finish |
An example value being Anodized. |
|
Roof - Frame - Colour |
The Roof - Frame - Colour of the Glazed enclosures. |
|
Roof - Glazing - System |
An example value being Bead-fixed. |
|
Roof - Glazing - Outer pane |
An example value being Heat strengthened glass. |
|
Roof - Glazing - Cavity space fill |
An example value being Air. |
|
Roof - Glazing - Inner pane |
An example value being Low emissivity glass. |
|
Roof - Glazing - Colour |
The Roof - Glazing - Colour of the Glazed enclosures. |
|
Walls - Performance criteria |
The Walls - Performance criteria of the Glazed enclosures. |
|
Walls - Frame - Material |
An example value being Aluminium. |
|
Walls - Frame - Thermal break |
An example value being Required. |
|
Walls - Frame - Finish |
An example value being Anodized. |
|
Walls - Glazing - System |
An example value being Bead-fixed. |
|
Walls - Glazing - Outer pane |
An example value being Laminated. |
|
Walls - Glazing - Cavity space fill |
An example value being Air. |
|
Walls - Glazing - Inner pane |
An example value being Thermally toughened glass. |
|
Walls - Glazing - Colour |
The Walls - Glazing - Colour of the Glazed enclosures. |
|
Ventilation - Purge |
An example value being Automatic glazed roof vents with thermostatic control. |
|
Ventilation - Supplementary |
An example value being Trickle vents in windows. |
|
Ventilation - Extract |
An example value being Mechanical extract. |
|
Hardware |
An example value being Lockable casement handles. |
|
Rainwater drainage |
An example value being Cast aluminium guttering and downpipes. |
|
Flashings - Location |
An example value being Cavity trays and stepped flashing along abutment of roof to main building. |
|
Flashings - Material |
An example value being Aluminium. |
|
Sealant - Location |
An example value being At junction with existing building. |
|
Sealant - Type |
An example value being Polysulfide. |
|
Floor - Material |
An example value being Engineered wood. |
|
Floor - Colour, species, texture |
The Floor - Colour, species, texture of the Glazed enclosures. |
|
Accessibility |
An example value being In accordance with BS 8300-1 and. |
|
Accessories |
An example value being Benches. |
|