Concrete glazed stair landing panels

Precast concrete glazed stair landing panels are described by characteristics such as panel size, nosing and provision for nosing insert. An example use may be within a precast stair tread and landing glazing system.

Uniclass2015 - Pr_25_30_90_12 Concrete glazed stair landing panels
Reference Notes
NBS Code

45-20-60/370 Precast concrete glazed stair landing panels

-
Download manufacturer object defintion template

Manufacturer Product Data template

Complete this electronic spreadsheet to ensure that your Concrete glazed stair landing panels product information meets the requirements of Level 2 BIM. This is important as it will enable your customers to select, specify and use your products within the BIM environment. Once you have completed this template you can host it on your own website or distribute it to your customers. Please note that we do not host completed product data templates within the BIM Toolkit.

2

Requirement

Visual information to provide general principles of the design. Showing arrangement of system with their relationship to internal and external context, and key project criteria to suit a clients brief. General descriptions would be expected to communicate principles of materiality, scope, colour and context. Expect strategic coordination with other professions to show general principles of the design.

Purpose of information

To provide a visual representation of proposals at a Concept stage and support general spatial coordination.

Plan

The above illustration is for Glazed floorlight panels from the NBS section Pavement and floor light products. This is indicative of the LOD requirements for Concrete glazed stair landing panels.

3

Requirement

Visual information to provide developed principles of the design to a greater level of detail. Developed coordination between all professions. Visual development showing coordination for general size and primary relationships between different elements of the construction. Can form a brief for a specialist sub-contractor or fabricator to progress with their technical design, fabrication and installation. This would be expected to include critical dimensional coordination, performance requirements and qualities of finish.

Purpose of information

To provide a visual representation of proposals, confirming brief for technical Design stage supporting full spatial coordination.

Plan
Model
2D Detail
Schedule

The above illustrations are for Glazed floorlight panels from the NBS section Pavement and floor light products. This is indicative of the LOD requirements for Concrete glazed stair landing panels.

4

Requirement

Information to be updated to reflect 'Final Construction Issue'. All anchors, supports & anti-vibration mounts to be modelled.

Purpose of information

To be updated during the construction process to reflect the final design, and to provide a future reference to sit alongside the O&M Manuals.

Plan
Model
2D Section
2D Detail
Schedule

The above illustrations are for Glazed floorlight panels from the NBS section Pavement and floor light products. This is indicative of the LOD requirements for Concrete glazed stair landing panels.

5

Requirement

Visual information to provide full information to support construction / installation. Developed coordination between all professions. Visual representations showing final coordination for size and relationships between different elements of the construction. Graphical representation of system, dimensionally accurate indicating primary performance characteristics and sufficient information to support installation. Typical / Installation details separately produced linked to model element and adjacent constructions.

Purpose of information

To be updated during the construction process to reflect the final design, and to provide a future reference to sit alongside the O&M Manuals.

Plan
Model
2D Section
2D Detail
Schedule

The above illustrations are for Glazed floorlight panels from the NBS section Pavement and floor light products. This is indicative of the LOD requirements for Concrete glazed stair landing panels.

Download manufacturer object defintion template

Manufacturer Product Data template

Complete this electronic spreadsheet to ensure that your Concrete glazed stair landing panels product information meets the requirements of Level 2 BIM. This is important as it will enable your customers to select, specify and use your products within the BIM environment. Once you have completed this template you can host it on your own website or distribute it to your customers. Please note that we do not host completed product data templates within the BIM Toolkit.

2

Provide an outline description of the deliverable.

Name Definition
Description A description of the type of object to detail any design intent.
3

Provide an outline description of the deliverable.

Name Definition
Description A description of the type of object to detail any design intent.
4

Provide enough information to allow the selection of the manufacturer product to meet requirements. This information may also be used to replace the installed product during the operation stage of the building's lifecycle. Information covering the execution of the deliverable should also be provided in the associated specification.

Name Definition
Manufacturer The Manufacturer of the Concrete glazed stair landing panels.
Panel size - Overall size (length x width x depth) The Panel size - Overall size (length x width x depth) of the Concrete glazed stair landing panels.
Panel size - Clear span The Panel size - Clear span of the Concrete glazed stair landing panels.
Panel size - Bearing (minimum) An example value being 75 mm.
Nosing An example value being 25 mm diameter bullnose.
Provision for nosing insert The Provision for nosing insert of the Concrete glazed stair landing panels.
Glazing units - Type An example value being Block.
Glazing units - Standard An example value being To BS EN 1051-1, class I and.
Glazing units - Form An example value being A. to BS EN 1051-1.
Glazing units - (I x b) An example value being 93 x 93 mm.
Glazing units - Thickness (h) An example value being 15 mm.
Glazing units - Pattern The Glazing units - Pattern of the Concrete glazed stair landing panels.
Glazing units - Colour An example value being Natural.
Glazing units - Surface finish An example value being Manufacturer's recommended slip resistant coating.
Concrete - Type An example value being Proprietary to BS 8500-1 and.
Concrete - Conformity An example value being In accordance with BS 8500-1, Annex A4 for the specified exposure class and to.
Concrete - Identity An example value being Manufacturer's mix reference.
Concrete - Exposure class to BS 8500 An example value being XC1.
Concrete - Colour An example value being Natural.
Concrete - Wearing surface finish An example value being Exposed aggregate.
Concrete - Soffit surface finish An example value being As cast.
Concrete reinforcement - Carbon steel An example value being To BS 4449, BS 4482, BS 4483 and BS EN 13877-3 as appropriate.
Concrete reinforcement - Cutting and bending An example value being To BS 8666.
Concrete reinforcement - Condition at time of placement An example value being Clean, free of corrosive pitting, loose materials and substances that may adversely affect reinforcement, concrete, or bond between the two.
Cast-in lifting sockets An example value being Two zinc plated steel anchor sockets per panel.
Cast in fixing sockets An example value being Four zinc plated steel anchor sockets per panel.
Panel accessories An example value being Stainless steel closure caps to lifting points.
5

Provide the information specific to the selected manufacturer and product reference. Information covering the execution of the deliverable should also be provided in the associated specification.

Name Definition
Manufacturer The Manufacturer of the Concrete glazed stair landing panels.
Panel size - Overall size (length x width x depth) The Panel size - Overall size (length x width x depth) of the Concrete glazed stair landing panels.
Panel size - Clear span The Panel size - Clear span of the Concrete glazed stair landing panels.
Panel size - Bearing (minimum) An example value being 75 mm.
Nosing An example value being 25 mm diameter bullnose.
Provision for nosing insert The Provision for nosing insert of the Concrete glazed stair landing panels.
Glazing units - Type An example value being Block.
Glazing units - Standard An example value being To BS EN 1051-1, class I and.
Glazing units - Form An example value being A. to BS EN 1051-1.
Glazing units - (I x b) An example value being 93 x 93 mm.
Glazing units - Thickness (h) An example value being 15 mm.
Glazing units - Pattern The Glazing units - Pattern of the Concrete glazed stair landing panels.
Glazing units - Colour An example value being Natural.
Glazing units - Surface finish An example value being Manufacturer's recommended slip resistant coating.
Concrete - Type An example value being Proprietary to BS 8500-1 and.
Concrete - Conformity An example value being In accordance with BS 8500-1, Annex A4 for the specified exposure class and to.
Concrete - Identity An example value being Manufacturer's mix reference.
Concrete - Exposure class to BS 8500 An example value being XC1.
Concrete - Colour An example value being Natural.
Concrete - Wearing surface finish An example value being Exposed aggregate.
Concrete - Soffit surface finish An example value being As cast.
Concrete reinforcement - Carbon steel An example value being To BS 4449, BS 4482, BS 4483 and BS EN 13877-3 as appropriate.
Concrete reinforcement - Cutting and bending An example value being To BS 8666.
Concrete reinforcement - Condition at time of placement An example value being Clean, free of corrosive pitting, loose materials and substances that may adversely affect reinforcement, concrete, or bond between the two.
Cast-in lifting sockets An example value being Two zinc plated steel anchor sockets per panel.
Cast in fixing sockets An example value being Four zinc plated steel anchor sockets per panel.
Panel accessories An example value being Stainless steel closure caps to lifting points.
6

Provide the information specific to the installed deliverable that is required for operation and maintenance. Information covering the detailed maintenance should also be provided in the associated PDF manuals.

Name Definition
Asset type An indication of whether the object is fixed or movable.
Manufacturer Email address for the organisation responsible for supplying or manufacturing the object
ModelNumber The product, item or unit number assigned by the manufacturer of the object.
Warranty guarantor (parts) Email address for the organisation responsible for the parts warranty.
Warranty duration (parts) Duration of parts warranty.
Warranty guarantor (labour) Email address for the organisation responsible for the labour warranty.
Warranty duration (labour) Duration of labour warranty.
Warranty duration unit Duration of warranties (typical value is 'years').
Replacement cost An indicative cost for unit replacement.
Expected life The typical service life of the object.
Duration unit Duration of expected life (typical value is 'years')
Warranty description Description of the warranty content and any exclusions.
Nominal length Typically the larger or primary horizontal dimension.
Nominal width Nominal width of product, typically the characteristic or secondary horizontal or characteristic dimension.
Nominal height Typically the vertical or secondary characteristic dimension.
ModelReference The name of the object as used by the manufacturer.
Shape Characteristic shape of product.
Size Characteristic size of product.
Colour Characteristic or primary colour of product.
Finish Characteristic or primary finish of product.
Grade Standard grading which the product corresponds.
Material Characteristic or primary material of product.
Constituents Optional constituent features, parts or finishes.
Features Other important characteristics or features relevant to product specification.
Accessibility performance The accessibility issue(s) which the object satisfies.
Sustainability performance Description of the sustainability issue(s) which the object satisfies
Code performance The code compliance requirement(s) which the object satisfies
Serial number The serial number assigned to an occurrence of a product by the manufacturer (per instance).
Installation date The date that the manufactured item was installed (per instance).
Warranty start date The date on which the warranty commences.
Tag number The tag number assigned to an occurrence of a product by the occupier (per instance).
Bar code The identity of the bar code (or rfid) given to an occurrence of the product (per instance).
Asset identifier The identification assigned to an asset that enables its differentiation from other assets.