Concrete containment parapet units

Precast concrete vehicle containment parapet units are described by characteristics such as parapet type, containment level and parapet height. An example use may be within a precast concrete vehicle containment parapet system.

Uniclass2015 - Pr_25_71_57_17 Concrete containment parapet units
Reference Notes
NBS Code

45-25-05/316 Precast concrete vehicle containment parapet units

-
Download manufacturer object defintion template

Manufacturer Product Data template

Complete this electronic spreadsheet to ensure that your Concrete containment parapet units product information meets the requirements of Level 2 BIM. This is important as it will enable your customers to select, specify and use your products within the BIM environment. Once you have completed this template you can host it on your own website or distribute it to your customers. Please note that we do not host completed product data templates within the BIM Toolkit.

2

Requirement

Visual information to provide general principles of the design. Showing arrangement of external surfacing materials, and key project criteria to suit a client’s brief. General descriptions would be expected to communicate principles of materiality, scope, colour and context. Expect strategic co-ordination with other professions, such as architects and engineers (civils & highways), to show general principles of the design.

Purpose of information

To provide a visual representation of proposals at a Concept Stage and support general spatial co-ordination.

Plan

The above illustration is for Composite fence panels from the NBS section Barrier and fence panels. This is indicative of the LOD requirements for Concrete containment parapet units.

3

Requirement

Visual information to provide developed principles of the design to a greater level of detail. Developed coordination between relevant professions, such as architects and civil engineers. Visual development showing co-ordination for general area and primary relationships between other elements of the external works construction.

Purpose of information

To provide a visual representation of proposals, confirming brief for Technical Design stage supporting full spatial co-ordination.

Plan
2D Section

The above illustrations are for Composite fence panels from the NBS section Barrier and fence panels. This is indicative of the LOD requirements for Concrete containment parapet units.

4

Requirement

Information to be updated to production level of information and to link drawn information back to external works specification.

Purpose of information

To provide sufficient information for contractor to issue to sub-contractors and to refine the external works construction programme.

Plan
2D Section

The above illustrations are for Composite fence panels from the NBS section Barrier and fence panels. This is indicative of the LOD requirements for Concrete containment parapet units.

5

Requirement

Visual information to provide finalised set of information to support construction / installation. Visual representations showing final co-ordination between relevant professions, such as architects and engineers, for area and relationships between other elements of the external works construction. Typical installation details produced separately linked to model element and adjacent constructions. Information to be updated to reflect ‘Final Construction Issue’.

Purpose of information

To be updated during the construction process to reflect the final design, and to provide a future reference to sit alongside the O&M Manuals.

Plan
2D Section

The above illustrations are for Composite fence panels from the NBS section Barrier and fence panels. This is indicative of the LOD requirements for Concrete containment parapet units.

Download manufacturer object defintion template

Manufacturer Product Data template

Complete this electronic spreadsheet to ensure that your Concrete containment parapet units product information meets the requirements of Level 2 BIM. This is important as it will enable your customers to select, specify and use your products within the BIM environment. Once you have completed this template you can host it on your own website or distribute it to your customers. Please note that we do not host completed product data templates within the BIM Toolkit.

2

Provide an outline description of the deliverable.

Name Definition
Description A description of the type of object to detail any design intent.
3

Provide an outline description of the deliverable.

Name Definition
Description A description of the type of object to detail any design intent.
4

Provide enough information to allow the selection of the manufacturer product to meet requirements. This information may also be used to replace the installed product during the operation stage of the building's lifecycle. Information covering the execution of the deliverable should also be provided in the associated specification.

Name Definition
Manufacturer The Manufacturer of the Concrete containment parapet units.
Parapet type An example value being Precast concrete parapet unit in accordance with BS 6779-2.
Containment level An example value being Normal - without shear transfer between panels.
Parapet height - Overall height from datum An example value being 1000 mm.
Parapet height - Top of concrete from datum An example value being 400 mm.
Panel length The Panel length of the Concrete containment parapet units.
Materials - Concrete An example value being To BS 5400-7 and BS 5400-8.
Materials - Joint plates An example value being For combined metal and precast concrete parapet units- 15 mm grade 316 S33 stainless steel to BS 1449-2 - greased and double wrapped in polyethylene.
Finishes The Finishes of the Concrete containment parapet units.
Colour An example value being Natural.
5

Provide the information specific to the selected manufacturer and product reference. Information covering the execution of the deliverable should also be provided in the associated specification.

Name Definition
Manufacturer The Manufacturer of the Concrete containment parapet units.
Parapet type An example value being Precast concrete parapet unit in accordance with BS 6779-2.
Containment level An example value being Normal - without shear transfer between panels.
Parapet height - Overall height from datum An example value being 1000 mm.
Parapet height - Top of concrete from datum An example value being 400 mm.
Panel length The Panel length of the Concrete containment parapet units.
Materials - Concrete An example value being To BS 5400-7 and BS 5400-8.
Materials - Joint plates An example value being For combined metal and precast concrete parapet units- 15 mm grade 316 S33 stainless steel to BS 1449-2 - greased and double wrapped in polyethylene.
Finishes The Finishes of the Concrete containment parapet units.
Colour An example value being Natural.
6

Provide the information specific to the installed deliverable that is required for operation and maintenance. Information covering the detailed maintenance should also be provided in the associated PDF manuals.

Name Definition
Asset type An indication of whether the object is fixed or movable.
Manufacturer Email address for the organisation responsible for supplying or manufacturing the object
ModelNumber The product, item or unit number assigned by the manufacturer of the object.
Warranty guarantor (parts) Email address for the organisation responsible for the parts warranty.
Warranty duration (parts) Duration of parts warranty.
Warranty guarantor (labour) Email address for the organisation responsible for the labour warranty.
Warranty duration (labour) Duration of labour warranty.
Warranty duration unit Duration of warranties (typical value is 'years').
Replacement cost An indicative cost for unit replacement.
Expected life The typical service life of the object.
Duration unit Duration of expected life (typical value is 'years')
Warranty description Description of the warranty content and any exclusions.
Nominal length Typically the larger or primary horizontal dimension.
Nominal width Nominal width of product, typically the characteristic or secondary horizontal or characteristic dimension.
Nominal height Typically the vertical or secondary characteristic dimension.
ModelReference The name of the object as used by the manufacturer.
Shape Characteristic shape of product.
Size Characteristic size of product.
Colour Characteristic or primary colour of product.
Finish Characteristic or primary finish of product.
Grade Standard grading which the product corresponds.
Material Characteristic or primary material of product.
Constituents Optional constituent features, parts or finishes.
Features Other important characteristics or features relevant to product specification.
Accessibility performance The accessibility issue(s) which the object satisfies.
Sustainability performance Description of the sustainability issue(s) which the object satisfies
Code performance The code compliance requirement(s) which the object satisfies
Serial number The serial number assigned to an occurrence of a product by the manufacturer (per instance).
Installation date The date that the manufactured item was installed (per instance).
Warranty start date The date on which the warranty commences.
Tag number The tag number assigned to an occurrence of a product by the occupier (per instance).
Bar code The identity of the bar code (or rfid) given to an occurrence of the product (per instance).
Asset identifier The identification assigned to an asset that enables its differentiation from other assets.