Provide enough information to allow the selection of the manufacturer product to meet requirements. This information may also be used to replace the installed product during the operation stage of the building's lifecycle. Information covering the execution of the deliverable should also be provided in the associated specification.
Name |
Definition |
|
Manufacturer |
The Manufacturer of the Wood doorsets. |
|
Third-party certification |
The Third-party certification of the Wood doorsets. |
|
Standard |
An example value being External non-fire rated doorset CE marked in accordance with BS EN 14351-1. |
|
Wood in joinery standard |
An example value being To BS EN 942. |
|
Configuration |
An example value being Double leaf, single action. |
|
Doorset size |
The Doorset size of the Wood doorsets. |
|
Performance - Fire resistance - Integrity |
The Performance - Fire resistance - Integrity of the Wood doorsets. |
|
Performance - Fire resistance - Insulation |
The Performance - Fire resistance - Insulation of the Wood doorsets. |
|
Performance - Fire resistance - Radiation |
The Performance - Fire resistance - Radiation of the Wood doorsets. |
|
Performance - Smoke leakage |
The Performance - Smoke leakage of the Wood doorsets. |
|
Performance - Reaction to fire |
The Performance - Reaction to fire of the Wood doorsets. |
|
Performance - Acoustic performance |
An example value being To BS EN ISO 10140-2, sound reduction index Rw 35 dB minimum. |
|
Performance - Strength and durability |
An example value being To BS EN 1192, Class 1. |
|
Performance - Thermal |
The Performance - Thermal of the Wood doorsets. |
|
Performance - Intruder resistance - Minimum requirement |
An example value being In accordance with BS 6375-3, Basic security. |
|
Performance - Intruder resistance - Application |
An example value being Both sides. |
|
Performance - Intruder resistance - Conformity |
An example value being Certification by accredited third-party certification body. Type testing not permitted. |
|
Performance - Bullet resistance |
An example value being To BS EN 1522, Class FB3. |
|
Performance - Explosion resistance - Blast duration |
The Performance - Explosion resistance - Blast duration of the Wood doorsets. |
|
Performance - Explosion resistance - Pressure mode |
An example value being Continuous static. |
|
Performance - Explosion resistance - Overpressure (maximum) |
An example value being 10 kN/m². |
|
Performance - Explosion resistance - Rebound pressure (maximum) |
An example value being 20% of maximum overpressure. |
|
Performance - Accessibility |
The Performance - Accessibility of the Wood doorsets. |
|
Frame - Material |
An example value being Hardwood. |
|
Frame - Species |
An example value being American white oak. |
|
Frame - Appearance class |
An example value being J10. |
|
Frame - Threshold |
The Frame - Threshold of the Wood doorsets. |
|
Frame - Perimeter seals or inserts |
An example value being Acoustic seal. |
|
Frame - Finish |
An example value being Primed ready for site finish. |
|
Frame - Colour |
The Frame - Colour of the Wood doorsets. |
|
Frame - External |
The Frame - External of the Wood doorsets. |
|
Frame - Internal |
An example value being As External. |
|
Frame - Installation fasteners |
An example value being Galvanized carbon steel frame cramps. |
|
Frame - Frame accessories |
An example value being Head ventilator. |
|
Door leaf - Thickness |
An example value being 35 mm. |
|
Door leaf - Core |
An example value being Solid core. |
|
Door leaf - Appearance class |
An example value being J10. |
|
Door leaf - Panel details |
The Door leaf - Panel details of the Wood doorsets. |
|
Door leaf - Facings |
An example value being Hardboard. |
|
Door leaf - Species |
An example value being Hardwood. |
|
Door leaf - Cut |
An example value being Crown cut veneer. |
|
Door leaf - Lippings |
An example value being Concealed lippings to long edges. |
|
Door leaf - Perimeter seals |
An example value being Acoustic. |
|
Door leaf - Finish |
An example value being Primed ready for site finish. |
|
Door leaf - Colour - External |
The Door leaf - Colour - External of the Wood doorsets. |
|
Door leaf - Colour - Internal |
An example value being As External. |
|
Door leaf - Glazing - Type |
An example value being Clear double safety glazing in accordance with BS 6262-4. |
|
Door leaf - Glazing - Manifestation |
The Door leaf - Glazing - Manifestation of the Wood doorsets. |
|
Door leaf - Beading - Type |
An example value being External. |
|
Door leaf - Beading - Material |
An example value being Hardwood. |
|
Door leaf - Beading - Fixing |
The Door leaf - Beading - Fixing of the Wood doorsets. |
|
Door leaf - Door accessories |
An example value being Additional blockings for letter plate. |
|
Planted stops - Wood species |
An example value being American white oak. |
|
Planted stops - Appearance class |
An example value being J10. |
|
Planted stops - Finish |
An example value being Primed ready for site finish. |
|
Planted stops - Colour |
The Planted stops - Colour of the Wood doorsets. |
|
Hardware |
The Hardware of the Wood doorsets. |
|
Architraves - Material |
An example value being American white oak. |
|
Architraves - Wood appearance class |
An example value being To BS EN 942, Class J10. |
|
Architraves - Finish |
An example value being Primed ready for site finish. |
|
Architraves - Colour - External |
The Architraves - Colour - External of the Wood doorsets. |
|
Architraves - Colour - Internal |
An example value being As External. |
|
Preservative treatment |
An example value being Organic solvent. |
|
Accessories |
The Accessories of the Wood doorsets. |
|