Provide enough information to allow the selection of the manufacturer product to meet requirements. This information may also be used to replace the installed product during the operation stage of the building's lifecycle. Information covering the execution of the deliverable should also be provided in the associated specification.
Name |
Definition |
|
Manufacturer |
The Manufacturer of the Fire-resisting roller shutters. |
|
Standard |
An example value being External fire-rated roller shutter CE marked toBS EN 13241 and. |
|
Opening sizes |
The Opening sizes of the Fire-resisting roller shutters. |
|
Format |
An example value being External. |
|
Arrangement |
An example value being Horizontal. |
|
Performance - Fire performance - Fire resistance |
The Performance - Fire performance - Fire resistance of the Fire-resisting roller shutters. |
|
Performance - Fire performance - Smoke leakage |
The Performance - Fire performance - Smoke leakage of the Fire-resisting roller shutters. |
|
Performance - Watertightness |
An example value being To BS EN 12489, Class 0. |
|
Performance - Resistance to wind load |
An example value being To BS EN 12424, Class 0. |
|
Performance - Acoustic performance |
An example value being To BS EN ISO 10140-2, sound reduction index Rw 35 dB minimum. |
|
Performance - Thermal resistance |
The Performance - Thermal resistance of the Fire-resisting roller shutters. |
|
Performance - Air permeability |
An example value being To BS EN 12426, Class 0. |
|
Performance - Application - Conformity |
An example value being Certification by accredited third-party certification body. Type testing not permitted. |
|
Performance - Intruder resistance - Requirement |
An example value being In accordance with BS 6375-3, Basic security. |
|
Performance - Bullet resistance |
An example value being To BS EN 1522, Class FB3. |
|
Performance - Explosion resistance - Blast duration |
The Performance - Explosion resistance - Blast duration of the Fire-resisting roller shutters. |
|
Performance - Explosion resistance - Pressure mode |
An example value being Continuous static. |
|
Performance - Explosion resistance - Overpressure (maximum) |
An example value being 10 kN/m². |
|
Performance - Explosion resistance - Rebound pressure (maximum) |
An example value being 20% of maximum overpressure. |
|
Performance - Accessibility |
The Performance - Accessibility of the Fire-resisting roller shutters. |
|
Frame and guides - Material |
An example value being Aluminium. |
|
Frame and guides - Material - Perimeter seals or inserts |
An example value being Acoustic seal. |
|
Frame and guides - Material - Finish |
An example value being Full paint system. |
|
Frame and guides - Material - Colour |
The Frame and guides - Material - Colour of the Fire-resisting roller shutters. |
|
Frame and guides - Material - Film thickness (minimum) |
An example value being Coating applicator to determine. |
|
Frame and guides - Material - Installation fasteners |
An example value being Galvanized carbon steel frame cramps. |
|
Frame and guides - Material - Frame accessories |
An example value being Head ventilator. |
|
Shutter curtain - Lath material |
An example value being Aluminium. |
|
Shutter curtain - Profile |
An example value being Curved. |
|
Shutter curtain - Finish and colour |
The Shutter curtain - Finish and colour of the Fire-resisting roller shutters. |
|