Provide enough information to allow the selection of the manufacturer product to meet requirements. This information may also be used to replace the installed product during the operation stage of the building's lifecycle. Information covering the execution of the deliverable should also be provided in the associated specification.
Name |
Definition |
|
Manufacturer |
The Manufacturer of the Window panels. |
|
Panel configuration |
An example value being Bespoke. |
|
Third party product certification |
An example value being To Home Office requirements. |
|
Panel size - Overall size (width x height x depth) |
The Panel size - Overall size (width x height x depth) of the Window panels. |
|
Aperture/ window opening - Inside (width x height) |
The Aperture/ window opening - Inside (width x height) of the Window panels. |
|
Aperture/ window opening - Outside (width x height) |
The Aperture/ window opening - Outside (width x height) of the Window panels. |
|
Glazing configuration |
An example value being Double lens/ paver. |
|
Glazing units - Type |
An example value being Block. |
|
Glazing units - Standard |
An example value being To BS EN 1051-1, class II, compressive strength category F and BS EN 1051-2.To BS EN 1051-1, class III, compressive strength category F and BS EN 1051-2. |
|
Glazing units - Form |
An example value being A. to BS EN 1051-1. |
|
Glazing units - Face dimensions (I x b) |
An example value being 127 x 127 mm. |
|
Glazing units - Centre spacing |
An example value being 165 mm. |
|
Glazing units - Pattern |
The Glazing units - Pattern of the Window panels. |
|
Glazing units - Colour |
An example value being Natural. |
|
Concrete - Type |
An example value being Proprietary to BS 8500-1 and BS 8500-2. |
|
Concrete - Conformity |
An example value being In accordance with BS 8500-1, Annex A.4 for the specified exposure class and to. |
|
Concrete - Identity |
An example value being Manufacturer's mix reference. |
|
Concrete - Exposure class to BS 8500 |
An example value being XC1. |
|
Concrete - Colour |
An example value being Natural. |
|
Concrete - Surface finish |
An example value being Exposed aggregate. |
|
Concrete reinforcement - Carbon steel |
An example value being To BS 4449, BS 4482, BS 4483 and BS EN 13877-3 as appropriate. |
|
Concrete reinforcement - Cutting and bending |
An example value being To BS 8666. |
|
Concrete reinforcement - Condition at time of placement |
An example value being Clean, free of corrosive pitting, loose materials and substances that may adversely affect reinforcement, concrete, or bond between the two. |
|
Cast in sleeved fixing holes - Size, number and location |
An example value being 4 equally spaced 20 mm diameter metal sleeve lined holes through depth of panel to each vertical side (8 number sleeves). |
|
Cast in sleeved fixing holes - Head recesses |
An example value being Each fixing hole to have 40 mm diameter x 25 mm deep recess to outside face. |
|
Cast in sleeved fixing holes - Material |
An example value being Carbon steel. |
|
Cast-in lifting sockets |
An example value being Not required. |
|