Provide enough information to allow the selection of the manufacturer product to meet requirements. This information may also be used to replace the installed product during the operation stage of the building's lifecycle. Information covering the execution of the deliverable should also be provided in the associated specification.
Name |
Definition |
|
Manufacturer |
The Manufacturer of the Window units. |
|
Standard |
An example value being Non-fire- and/ or smoke-rated windows to BS EN 14351-1 and. |
|
Third-party certification |
The Third-party certification of the Window units. |
|
Dimensions and configurations |
The Dimensions and configurations of the Window units. |
|
Product performance - Fire performance - Fire resistance |
The Product performance - Fire performance - Fire resistance of the Window units. |
|
Product performance - Fire performance - Fire egress |
The Product performance - Fire performance - Fire egress of the Window units. |
|
Product performance - Weather performance - UK exposure category |
An example value being To BS 6375-1, 800 Pa. |
|
Product performance - Weather performance - Air permeability |
An example value being To BS 6375-1, Class 2. |
|
Product performance - Weather performance - Watertightness |
An example value being To BS 6375-1, Class 3A. |
|
Product performance - Weather performance - Resistance to wind load |
An example value being To BS 6375-1, Class A2. |
|
Product performance - Durability - Operation and strength characteristics |
An example value being To BS 6375-2. |
|
Product performance - Durability - Load bearing capacity of safety devices |
The Product performance - Durability - Load bearing capacity of safety devices of the Window units. |
|
Product performance - Safety - Anti-ligature standard |
An example value being In accordance with DHF TS001, Grade 1. |
|
Product performance - Safety - Security level |
An example value being To Secured by Design standard. |
|
Product performance - Environmental - Frame to glazing ratio (maximum) |
The Product performance - Environmental - Frame to glazing ratio (maximum) of the Window units. |
|
Product performance - Environmental - Background ventilation |
The Product performance - Environmental - Background ventilation of the Window units. |
|
Product performance - Environmental - Acoustic performance rating |
An example value being To BS EN ISO 717-1, 34 dB. |
|
Product performance - Thermal - Whole window U-value |
An example value being 0.7 W/mK. |
|
Product performance - Thermal - British Fenestration Rating Council Window Energy Rating |
An example value being A. |
|
Frame - Profile |
The Frame - Profile of the Window units. |
|
Frame - Finish as delivered - Coating |
An example value being Anodized to BS EN 3987. |
|
Frame - Finish as delivered - Colour |
The Frame - Finish as delivered - Colour of the Window units. |
|
Frame - Finish as delivered - Film thickness (minimum) |
An example value being Coating applicator to determine. |
|
Frame - Ventilator |
The Frame - Ventilator of the Window units. |
|
Glazing or infill - Standard |
An example value being Relevant parts of BS EN 1279. |
|
Glazing or infill - Requirements |
The Glazing or infill - Requirements of the Window units. |
|
Hardware |
The Hardware of the Window units. |
|
Operation |
The Operation of the Window units. |
|
Operation - Type |
An example value being Manual. |
|
Operation - Electrical supply |
The Operation - Electrical supply of the Window units. |
|
Fixing features |
The Fixing features of the Window units. |
|