Provide enough information to allow the selection of the manufacturer product to meet requirements. This information may also be used to replace the installed product during the operation stage of the building's lifecycle. Information covering the execution of the deliverable should also be provided in the associated specification.
Name |
Definition |
|
Manufacturer |
The Manufacturer of the Wood window units. |
|
Standard |
An example value being Non-fire- and/ or smoke-rated windows to BS EN 14351-1 and. |
|
Third-party certification |
The Third-party certification of the Wood window units. |
|
Dimensions and configurations |
The Dimensions and configurations of the Wood window units. |
|
Product performance - Fire performance - Fire resistance |
The Product performance - Fire performance - Fire resistance of the Wood window units. |
|
Product performance - Fire performance - Fire egress |
The Product performance - Fire performance - Fire egress of the Wood window units. |
|
Product performance - Weather performance - UK exposure category |
An example value being To BS 6375-1, 800 Pa. |
|
Product performance - Weather performance - Air permeability |
An example value being To BS 6375-1, Class 2. |
|
Product performance - Weather performance - Watertightness |
An example value being To BS 6375-1, Class 3A. |
|
Product performance - Weather performance - Resistance to wind load |
An example value being To BS 6375-1, Class A2. |
|
Product performance - Durability - Operation and strength characteristics |
An example value being To BS 6375-2. |
|
Product performance - Durability - Loadbearing capacity of safety devices |
The Product performance - Durability - Loadbearing capacity of safety devices of the Wood window units. |
|
Product performance - Safety - User design standards |
An example value being In accordance with BS 8213-1. |
|
Product performance - Safety - Anti-ligature standard |
An example value being In accordance with DHF TS001, Grade 1. |
|
Product performance - Safety - Security level |
An example value being To Secured by Design standard. |
|
Product performance - Environmental - Frame to glazing ratio (maximum) |
The Product performance - Environmental - Frame to glazing ratio (maximum) of the Wood window units. |
|
Product performance - Environmental - Background ventilation |
The Product performance - Environmental - Background ventilation of the Wood window units. |
|
Product performance - Environmental - Acoustic performance rating |
An example value being To BS EN ISO 717-1, 34 dB. |
|
Product performance - Thermal - Whole window U-value |
An example value being 0.7 W/mK. |
|
Product performance - Thermal - British Fenestration Rating Council Window Energy Rating |
An example value being A. |
|
Frame - Standard |
An example value being To BS EN 942. |
|
Frame - Profile |
The Frame - Profile of the Wood window units. |
|
Frame - Wood species |
An example value being American white oak. |
|
Frame - Chain of custody |
An example value being CSA. |
|
Frame - Appearance class |
An example value being For opaque finishing: to BS EN 942, J10 for glazing beads, drip mouldings and the like. J40 or better for all other members. |
|
Frame - Finish as delivered |
An example value being Primer. |
|
Frame - Preservative treatment to wood components |
The Frame - Preservative treatment to wood components of the Wood window units. |
|
Frame - Ventilator |
The Frame - Ventilator of the Wood window units. |
|
Frame - Frame horns |
An example value being Required. |
|
Glazing or infill - Standard |
An example value being Relevant parts of BS EN 1279. |
|
Glazing or infill - Requirements |
The Glazing or infill - Requirements of the Wood window units. |
|
Hardware |
The Hardware of the Wood window units. |
|
Operation - Type |
An example value being Manual. |
|
Operation - Electrical supply |
The Operation - Electrical supply of the Wood window units. |
|
Fixing features |
The Fixing features of the Wood window units. |
|