Dissolved air flotation plants

Dissolved air flotation plant are described by characteristics such as power, supply voltage and nominal frequency.

Uniclass2015 - Pr_60_45_07_22 Dissolved air flotation plants
Reference Notes
NBS Code

90-07-07/320 Dissolved air flotation plant

-
Download manufacturer object defintion template

Manufacturer Product Data template

Complete this electronic spreadsheet to ensure that your Dissolved air flotation plants product information meets the requirements of Level 2 BIM. This is important as it will enable your customers to select, specify and use your products within the BIM environment. Once you have completed this template you can host it on your own website or distribute it to your customers. Please note that we do not host completed product data templates within the BIM Toolkit.

3

Requirement

Visual information to provide developed principles of the design to a greater level of detail. Developed coordination between all professions. Visual development showing coordination for general size and primary relationships between different elements of the construction. Can form a brief for a specialist sub-contractor or fabricator to progress with their technical design, fabrication and installation. This would be expected to include critical dimensional coordination, performance requirements and qualities of finish.

Purpose of information

To provide a visual representation of proposals, confirming brief for Technical Design stage supporting full spatial coordination.

Plan
Elevation
Model

The above illustrations are for Packaged lamella units from the NBS section Biological filtration wastewater treatment products. This is indicative of the LOD requirements for Dissolved air flotation plants.

4

Requirement

Visual information to provide fixed principles of the design supporting procurement. Developed coordination between all professions. Visual representations showing coordination for general size and relationships between different elements of the construction. Graphical representation of system, dimensionally accurate indicating primary performance characteristics. Graphical information represented may alter depending on visual information to be produced, e.g.: Scope of work drawings, setting out, etc. Typical / Installation details separately produced linked to model element and adjacent constructions.

Purpose of information

To provide a visual representation of proposals at a Technical Design stage supporting full spatial coordination.

Plan
Elevation
Model
2D Section

The above illustrations are for Packaged lamella units from the NBS section Biological filtration wastewater treatment products. This is indicative of the LOD requirements for Dissolved air flotation plants.

5

Requirement

Visual information to provide full information to support construction / installation. Developed coordination between all professions. Visual representations showing final coordination for size and relationships between different elements of the construction. Graphical representation of system, dimensionally accurate indicating primary performance characteristics and sufficient information to support installation. Typical / Installation details separately produced linked to model element and adjacent constructions.

Purpose of information

To be updated during the construction process to reflect the final design, and to provide a future reference to sit alongside the O&M Manuals.

Plan
Elevation
Model
2D Section

The above illustrations are for Packaged lamella units from the NBS section Biological filtration wastewater treatment products. This is indicative of the LOD requirements for Dissolved air flotation plants.

Download manufacturer object defintion template

Manufacturer Product Data template

Complete this electronic spreadsheet to ensure that your Dissolved air flotation plants product information meets the requirements of Level 2 BIM. This is important as it will enable your customers to select, specify and use your products within the BIM environment. Once you have completed this template you can host it on your own website or distribute it to your customers. Please note that we do not host completed product data templates within the BIM Toolkit.

2

Provide an outline description of the deliverable.

Name Definition
Description A description of the type of object to detail any design intent.
3

Provide an outline description of the deliverable.

Name Definition
Description A description of the type of object to detail any design intent.
4

Provide enough information to allow the selection of the manufacturer product to meet requirements. This information may also be used to replace the installed product during the operation stage of the building's lifecycle. Information covering the execution of the deliverable should also be provided in the associated specification.

Name Definition
Manufacturer The Manufacturer of the Dissolved air flotation plants.
Standard The Standard of the Dissolved air flotation plants.
Power The Power of the Dissolved air flotation plants.
Supply voltage The Supply voltage of the Dissolved air flotation plants.
Nominal frequency The Nominal frequency of the Dissolved air flotation plants.
Process fluid flow rates The Process fluid flow rates of the Dissolved air flotation plants.
Process fluid flow rates - Minimum The Process fluid flow rates - Minimum of the Dissolved air flotation plants.
Process fluid flow rates - Average The Process fluid flow rates - Average of the Dissolved air flotation plants.
Process fluid flow rates - Maximum The Process fluid flow rates - Maximum of the Dissolved air flotation plants.
Influent properties The Influent properties of the Dissolved air flotation plants.
Clarified process fluid properties The Clarified process fluid properties of the Dissolved air flotation plants.
Clarified process fluid properties - Turbidity The Clarified process fluid properties - Turbidity of the Dissolved air flotation plants.
Clarified process fluid properties - Colour (True/filtered) The Clarified process fluid properties - Colour (True/filtered) of the Dissolved air flotation plants.
Clarified process fluid properties - Residual coagulant content The Clarified process fluid properties - Residual coagulant content of the Dissolved air flotation plants.
Clarified process fluid properties - pH The Clarified process fluid properties - pH of the Dissolved air flotation plants.
Clarified process fluid properties - Dissolved organic carbon The Clarified process fluid properties - Dissolved organic carbon of the Dissolved air flotation plants.
Required sludge properties % dry solids The Required sludge properties % dry solids of the Dissolved air flotation plants.
Durability The Durability of the Dissolved air flotation plants.
Noise level at 1m (maximum) The Noise level at 1m (maximum) of the Dissolved air flotation plants.
Peak electrical demand (maximum allowable) The Peak electrical demand (maximum allowable) of the Dissolved air flotation plants.
Maximum allowable reduction in plant capacity during maintenance The Maximum allowable reduction in plant capacity during maintenance of the Dissolved air flotation plants.
Feed pump system The Feed pump system of the Dissolved air flotation plants.
Flocculation zone The Flocculation zone of the Dissolved air flotation plants.
Flocculation zone - Type of flocculation zone The Flocculation zone - Type of flocculation zone of the Dissolved air flotation plants.
Flocculation zone - Flocculation tank details The Flocculation zone - Flocculation tank details of the Dissolved air flotation plants.
Flocculation zone - Flocculation tank details - Number of tanks The Flocculation zone - Flocculation tank details - Number of tanks of the Dissolved air flotation plants.
Flocculation zone - Flocculation tank details - Tank dimensions The Flocculation zone - Flocculation tank details - Tank dimensions of the Dissolved air flotation plants.
Flocculation zone - Flocculation tank details - Tank volume The Flocculation zone - Flocculation tank details - Tank volume of the Dissolved air flotation plants.
Flocculation zone - Flocculation tank details - Tank material The Flocculation zone - Flocculation tank details - Tank material of the Dissolved air flotation plants.
Flocculation zone - Type of stirrer or mixer The Flocculation zone - Type of stirrer or mixer of the Dissolved air flotation plants.
Flotation zone The Flotation zone of the Dissolved air flotation plants.
Flotation zone - Tank dimensions The Flotation zone - Tank dimensions of the Dissolved air flotation plants.
Flotation zone - Tank volume The Flotation zone - Tank volume of the Dissolved air flotation plants.
Flotation zone - Tank material The Flotation zone - Tank material of the Dissolved air flotation plants.
Sludge removal system The Sludge removal system of the Dissolved air flotation plants.
Sludge removal system - Type of sludge removal system The Sludge removal system - Type of sludge removal system of the Dissolved air flotation plants.
Sludge removal system - Type of mechanical de-sludging system The Sludge removal system - Type of mechanical de-sludging system of the Dissolved air flotation plants.
Sludge removal system - Method of sludge discharge The Sludge removal system - Method of sludge discharge of the Dissolved air flotation plants.
Discharge pump system The Discharge pump system of the Dissolved air flotation plants.
5

Provide the information specific to the selected manufacturer and product reference. Information covering the execution of the deliverable should also be provided in the associated specification.

Name Definition
Manufacturer The Manufacturer of the Dissolved air flotation plants.
Standard The Standard of the Dissolved air flotation plants.
Power The Power of the Dissolved air flotation plants.
Supply voltage The Supply voltage of the Dissolved air flotation plants.
Nominal frequency The Nominal frequency of the Dissolved air flotation plants.
Process fluid flow rates The Process fluid flow rates of the Dissolved air flotation plants.
Process fluid flow rates - Minimum The Process fluid flow rates - Minimum of the Dissolved air flotation plants.
Process fluid flow rates - Average The Process fluid flow rates - Average of the Dissolved air flotation plants.
Process fluid flow rates - Maximum The Process fluid flow rates - Maximum of the Dissolved air flotation plants.
Influent properties The Influent properties of the Dissolved air flotation plants.
Clarified process fluid properties The Clarified process fluid properties of the Dissolved air flotation plants.
Clarified process fluid properties - Turbidity The Clarified process fluid properties - Turbidity of the Dissolved air flotation plants.
Clarified process fluid properties - Colour (True/filtered) The Clarified process fluid properties - Colour (True/filtered) of the Dissolved air flotation plants.
Clarified process fluid properties - Residual coagulant content The Clarified process fluid properties - Residual coagulant content of the Dissolved air flotation plants.
Clarified process fluid properties - pH The Clarified process fluid properties - pH of the Dissolved air flotation plants.
Clarified process fluid properties - Dissolved organic carbon The Clarified process fluid properties - Dissolved organic carbon of the Dissolved air flotation plants.
Required sludge properties % dry solids The Required sludge properties % dry solids of the Dissolved air flotation plants.
Durability The Durability of the Dissolved air flotation plants.
Noise level at 1m (maximum) The Noise level at 1m (maximum) of the Dissolved air flotation plants.
Peak electrical demand (maximum allowable) The Peak electrical demand (maximum allowable) of the Dissolved air flotation plants.
Maximum allowable reduction in plant capacity during maintenance The Maximum allowable reduction in plant capacity during maintenance of the Dissolved air flotation plants.
Feed pump system The Feed pump system of the Dissolved air flotation plants.
Flocculation zone The Flocculation zone of the Dissolved air flotation plants.
Flocculation zone - Type of flocculation zone The Flocculation zone - Type of flocculation zone of the Dissolved air flotation plants.
Flocculation zone - Flocculation tank details The Flocculation zone - Flocculation tank details of the Dissolved air flotation plants.
Flocculation zone - Flocculation tank details - Number of tanks The Flocculation zone - Flocculation tank details - Number of tanks of the Dissolved air flotation plants.
Flocculation zone - Flocculation tank details - Tank dimensions The Flocculation zone - Flocculation tank details - Tank dimensions of the Dissolved air flotation plants.
Flocculation zone - Flocculation tank details - Tank volume The Flocculation zone - Flocculation tank details - Tank volume of the Dissolved air flotation plants.
Flocculation zone - Flocculation tank details - Tank material The Flocculation zone - Flocculation tank details - Tank material of the Dissolved air flotation plants.
Flocculation zone - Type of stirrer or mixer The Flocculation zone - Type of stirrer or mixer of the Dissolved air flotation plants.
Flotation zone The Flotation zone of the Dissolved air flotation plants.
Flotation zone - Tank dimensions The Flotation zone - Tank dimensions of the Dissolved air flotation plants.
Flotation zone - Tank volume The Flotation zone - Tank volume of the Dissolved air flotation plants.
Flotation zone - Tank material The Flotation zone - Tank material of the Dissolved air flotation plants.
Sludge removal system The Sludge removal system of the Dissolved air flotation plants.
Sludge removal system - Type of sludge removal system The Sludge removal system - Type of sludge removal system of the Dissolved air flotation plants.
Sludge removal system - Type of mechanical de-sludging system The Sludge removal system - Type of mechanical de-sludging system of the Dissolved air flotation plants.
Sludge removal system - Method of sludge discharge The Sludge removal system - Method of sludge discharge of the Dissolved air flotation plants.
Discharge pump system The Discharge pump system of the Dissolved air flotation plants.
6

Provide the information specific to the installed deliverable that is required for operation and maintenance. Information covering the detailed maintenance should also be provided in the associated PDF manuals.

Name Definition
Asset type An indication of whether the object is fixed or movable.
Manufacturer Email address for the organisation responsible for supplying or manufacturing the object
ModelNumber The product, item or unit number assigned by the manufacturer of the object.
Warranty guarantor (parts) Email address for the organisation responsible for the parts warranty.
Warranty duration (parts) Duration of parts warranty.
Warranty guarantor (labour) Email address for the organisation responsible for the labour warranty.
Warranty duration (labour) Duration of labour warranty.
Warranty duration unit Duration of warranties (typical value is 'years').
Replacement cost An indicative cost for unit replacement.
Expected life The typical service life of the object.
Duration unit Duration of expected life (typical value is 'years')
Warranty description Description of the warranty content and any exclusions.
Nominal length Typically the larger or primary horizontal dimension.
Nominal width Nominal width of product, typically the characteristic or secondary horizontal or characteristic dimension.
Nominal height Typically the vertical or secondary characteristic dimension.
ModelReference The name of the object as used by the manufacturer.
Shape Characteristic shape of product.
Size Characteristic size of product.
Colour Characteristic or primary colour of product.
Finish Characteristic or primary finish of product.
Grade Standard grading which the product corresponds.
Material Characteristic or primary material of product.
Constituents Optional constituent features, parts or finishes.
Features Other important characteristics or features relevant to product specification.
Accessibility performance The accessibility issue(s) which the object satisfies.
Sustainability performance Description of the sustainability issue(s) which the object satisfies
Code performance The code compliance requirement(s) which the object satisfies
Serial number The serial number assigned to an occurrence of a product by the manufacturer (per instance).
Installation date The date that the manufactured item was installed (per instance).
Warranty start date The date on which the warranty commences.
Tag number The tag number assigned to an occurrence of a product by the occupier (per instance).
Bar code The identity of the bar code (or rfid) given to an occurrence of the product (per instance).
Asset identifier The identification assigned to an asset that enables its differentiation from other assets.