Provide enough information to allow the selection of the manufacturer product to meet requirements. This information may also be used to replace the installed product during the operation stage of the building's lifecycle. Information covering the execution of the deliverable should also be provided in the associated specification.
Name |
Definition |
|
Manufacturer |
The Manufacturer of the Air handling units. |
|
Standard |
An example value being To BS EN 13053. |
|
Duty - Air volume |
The Duty - Air volume of the Air handling units. |
|
Duty - External resistance |
The Duty - External resistance of the Air handling units. |
|
Duty - Discharge velocity |
The Duty - Discharge velocity of the Air handling units. |
|
Duty - Sound power level |
The Duty - Sound power level of the Air handling units. |
|
Environment |
An example value being External. |
|
Casing construction - Standard |
An example value being To BS EN 1886. |
|
Casing construction - Details |
An example value being Submit shop drawings and details of dimensions and weight. |
|
Casing construction - Casing class |
An example value being D1. |
|
Casing construction - Leakage class of casing |
An example value being L1. |
|
Casing construction - Filter bypass leakage |
An example value being To BS EN 1886, section 7. |
|
Casing construction - Thermal performance of casing - Thermal transmittance |
An example value being T1. |
|
Casing construction - Thermal performance of casing - Thermal bridging |
An example value being TB1. |
|
Casing construction - Acoustic insulation of casing |
An example value being To BS EN 1886, section 9. |
|
Casing construction - Fire protection |
An example value being Category A. |
|
Casing construction - Mechanical safety |
An example value being To BS EN 1886, section 11. |
|
Casing construction - Material |
An example value being Aluminium. |
|
Casing construction - Finish |
An example value being Painted. |
|
Casing construction - Air-handling unit feet |
The Casing construction - Air-handling unit feet of the Air handling units. |
|
Casing construction - Special requirements |
The Casing construction - Special requirements of the Air handling units. |
|
Arrangement |
An example value being Blow through. |
|
Method of support |
The Method of support of the Air handling units. |
|
Anti-vibration mountings |
An example value being Compression isolators. |
|
Components - Dampers - Purpose |
An example value being To BS EN 13053, Category A – On-off sections. |
|
Components - Dampers - Mixing temperature efficiency |
An example value being M1. |
|
Components - Dampers - Damper control |
An example value being Manual. |
|
Components - Dampers - Damper type |
An example value being Iris damper. |
|
Components - Dampers - Material |
An example value being Aluminium. |
|
Components - Dampers - Ancillaries |
An example value being Locking device. |
|
Components - Filters |
The Components - Filters of the Air handling units. |
|
Components - Humidifiers |
The Components - Humidifiers of the Air handling units. |
|
Components - Pre-heaters |
The Components - Pre-heaters of the Air handling units. |
|
Components - Re-heaters |
The Components - Re-heaters of the Air handling units. |
|
Components - Cooling coils |
The Components - Cooling coils of the Air handling units. |
|
Components - Heat recovery - Heat recovery equipment |
The Components - Heat recovery - Heat recovery equipment of the Air handling units. |
|
Components - Heat recovery - Heat recovery class |
An example value being Class H1. |
|
Components - Fans - Fan type |
The Components - Fans - Fan type of the Air handling units. |
|
Components - Fans - Average air velocity class |
An example value being Class V1. |
|
Components - Fans - Power input class |
An example value being Class P1. |
|
Components - Attenuators |
The Components - Attenuators of the Air handling units. |
|
Flexible connections |
An example value being To BESADW/144. |
|
Access - General |
An example value being Provide access openings and covers complete, including opening devices. |
|
Access - Seal |
An example value being To prevent excessive air leakage. |
|
Access - Seal durability |
An example value being For normal maintenance operations over at least 10 years. |
|
Access - Access type |
An example value being Hatches. |
|
Access - Access clear width (minimum) |
An example value being 400 mm. |
|
Access - Opening device |
An example value being Interlock door handles. |
|
Access - Components requiring access |
An example value being Air control dampers. |
|
Direction of airflow |
An example value being Horizontal. |
|
Accessories |
The Accessories of the Air handling units. |
|