Central battery supply units

D.c. central battery supply units are described by characteristics such as integral maintenance bypass, input and battery charger. An example use may be within a central battery supplied emergency lighting system.

Uniclass2015 - Pr_60_70_06_12 Central battery supply units
Reference Notes
NBS Code

90-60-40/430 d.c. central battery supply units

-
Download manufacturer object defintion template

Manufacturer Product Data template

Complete this electronic spreadsheet to ensure that your Central battery supply units product information meets the requirements of Level 2 BIM. This is important as it will enable your customers to select, specify and use your products within the BIM environment. Once you have completed this template you can host it on your own website or distribute it to your customers. Please note that we do not host completed product data templates within the BIM Toolkit.

2

Requirement

Visual information to provide general principles of the design. Showing arrangement of system with their relationship to internal and external context, and key project criteria to suit a clients brief. General descriptions would be expected to communicate principles of materiality, scope, colour and context. Expect strategic coordination with other professions to show general principles of the design.

Purpose of information

To provide a visual representation of proposals at a Concept stage and support general spatial coordination.

Plan
Model

The above illustrations are for Inverters from the NBS section Inverters and power devices. This is indicative of the LOD requirements for Central battery supply units.

3

Requirement

Visual information to provide developed principles of the design to a greater level of detail. Developed coordination between all professions. Visual development showing coordination for general size and primary relationships between different elements of the construction. Can form a brief for a specialist sub-contractor or fabricator to progress with their technical design, fabrication and installation. This would be expected to include critical dimensional coordination, performance requirements and qualities of finish.

Purpose of information

To provide a visual representation of proposals, confirming brief for technical Design stage supporting full spatial coordination.

Plan
Model

The above illustrations are for Inverters from the NBS section Inverters and power devices. This is indicative of the LOD requirements for Central battery supply units.

4

Requirement

Visual information to provide fixed principles of the design supporting procurement. Developed coordination between all professions. Visual representations showing coordination for general size and relationships between different elements of the construction. Graphical representation of system, dimensionally accurate indicating primary performance characteristics. Graphical information represented may alter dependant on visual information to be produced, eg: Scope of work drawings, setting out, floor loading etc Typical / Installation details separately produced linked to model element and adjacent constructions.

Purpose of information

To provide a visual representation of proposals at a Technical Design stage supporting full spatial coordination.

Plan
Elevation
Model

The above illustrations are for Inverters from the NBS section Inverters and power devices. This is indicative of the LOD requirements for Central battery supply units.

5

Requirement

Visual information to provide full information to support construction / installation. Developed coordination between all professions. Visual representations showing final coordination for size and relationships between different elements of the construction. Graphical representation of system, dimensionally accurate indicating primary performance characteristics and sufficient information to support installation. Typical / Installation details separately produced linked to model element and adjacent constructions.

Purpose of information

To be updated during the construction process to reflect the final design, and to provide a future reference to sit alongside the O&M Manuals.

Plan
Elevation
Model

The above illustrations are for Inverters from the NBS section Inverters and power devices. This is indicative of the LOD requirements for Central battery supply units.

Download manufacturer object defintion template

Manufacturer Product Data template

Complete this electronic spreadsheet to ensure that your Central battery supply units product information meets the requirements of Level 2 BIM. This is important as it will enable your customers to select, specify and use your products within the BIM environment. Once you have completed this template you can host it on your own website or distribute it to your customers. Please note that we do not host completed product data templates within the BIM Toolkit.

2

Provide an outline description of the deliverable.

Name Definition
Description A description of the type of object to detail any design intent.
3

Provide an outline description of the deliverable.

Name Definition
Description A description of the type of object to detail any design intent.
4

Provide enough information to allow the selection of the manufacturer product to meet requirements. This information may also be used to replace the installed product during the operation stage of the building's lifecycle. Information covering the execution of the deliverable should also be provided in the associated specification.

Name Definition
Manufacturer The Manufacturer of the Central battery supply units.
Standard An example value being To BS EN 50171.
Third party certification An example value being ICEL 1009.
Integral maintenance bypass An example value being Required.
Input - Nominal voltage An example value being Single phase 230 V a.c. ±10%.
Input - Nominal frequency An example value being 50 Hz. ±2%.
Battery charger - Type An example value being Electronic solid-state controller, constant voltage, current-limited.
Battery charger - Battery recharge time An example value being To 80% capacity within 12 hours and 100% capacity within 24 hours.
Change over contactor An example value being To BS 764.
d.c.output - Rated output apparent power An example value being 1.25 kV·A.
d.c.output - Nominal voltage An example value being 24 V d.c.
Controls, indicators and alarms - Status indicators - Indicate the following with green LED An example value being a.c. mains input to battery charger.
Controls, indicators and alarms - Status indicators - Indicate the following with amber LED An example value being Boost charge.
Controls, indicators and alarms - Status indicators - Indicate the following with red LED An example value being Battery charger failure.
Controls, indicators and alarms - LCD display - Display the following information An example value being Battery voltage.
Controls, indicators and alarms - Event log An example value being Record up to 64 fault occurrences including time and date for each occurrence. Provide user access to event log through LCD display.
Audible alarms - Type An example value being Integral alarm within central battery enclosure providing minimum 65 dBA at 1 m.
Audible alarms - Activation and reset An example value being Activated by any fault condition. Continuous output until fault cleared or alarm silenced. Silencing of the alarm must not clear LED status indication.
Common fault relay contact An example value being Volt free 230 V a.c.
Enclosure - Mounting arrangement An example value being Floor standing.
Enclosure - Ingress protection (minimum) An example value being To BS EN 60529, IP21.
Enclosure - Material and construction - Type An example value being Welded carbon steel. Assemble to prevent distortion when the complete enclosure is lifted or transported.
Enclosure - Material and construction - Finish An example value being Epoxy powder coated.
Enclosure - Material and construction - Colour The Enclosure - Material and construction - Colour of the Central battery supply units.
Enclosure - Lockable access doors An example value being Required.
Enclosure - Cable entry An example value being Removable gland plates, for top entry cables.
Enclosure - Ventilation arrangement An example value being Forced ventilation fans during emergency mode.
Enclosure - Fan failure alarms An example value being Required.
Noise emission - Sound pressure level in normal mode (maximum) An example value being 60 dBA at 1 m.
Noise emission - Sound pressure level in battery mode (maximum) An example value being 65 dBA at 1 m.
System efficiency (minimum) An example value being 85%.
Battery - Type An example value being Lead-acid plante cells.
Battery - Labelling An example value being Indelibly mark with year of manufacture and installation.
Integral distribution board - Number of outgoing ways An example value being One.
Integral distribution board - Protection devices An example value being Double pole mcbs.
Integral distribution board - Protection devices - Rating An example value being 6 A.
Integral distribution board - Spare ways An example value being Fit with blanks.
Accessories An example value being Test button to simulate mains failure.
5

Provide the information specific to the selected manufacturer and product reference. Information covering the execution of the deliverable should also be provided in the associated specification.

Name Definition
Manufacturer The Manufacturer of the Central battery supply units.
Standard An example value being To BS EN 50171.
Third party certification An example value being ICEL 1009.
Integral maintenance bypass An example value being Required.
Input - Nominal voltage An example value being Single phase 230 V a.c. ±10%.
Input - Nominal frequency An example value being 50 Hz. ±2%.
Battery charger - Type An example value being Electronic solid-state controller, constant voltage, current-limited.
Battery charger - Battery recharge time An example value being To 80% capacity within 12 hours and 100% capacity within 24 hours.
Change over contactor An example value being To BS 764.
d.c.output - Rated output apparent power An example value being 1.25 kV·A.
d.c.output - Nominal voltage An example value being 24 V d.c.
Controls, indicators and alarms - Status indicators - Indicate the following with green LED An example value being a.c. mains input to battery charger.
Controls, indicators and alarms - Status indicators - Indicate the following with amber LED An example value being Boost charge.
Controls, indicators and alarms - Status indicators - Indicate the following with red LED An example value being Battery charger failure.
Controls, indicators and alarms - LCD display - Display the following information An example value being Battery voltage.
Controls, indicators and alarms - Event log An example value being Record up to 64 fault occurrences including time and date for each occurrence. Provide user access to event log through LCD display.
Audible alarms - Type An example value being Integral alarm within central battery enclosure providing minimum 65 dBA at 1 m.
Audible alarms - Activation and reset An example value being Activated by any fault condition. Continuous output until fault cleared or alarm silenced. Silencing of the alarm must not clear LED status indication.
Common fault relay contact An example value being Volt free 230 V a.c.
Enclosure - Mounting arrangement An example value being Floor standing.
Enclosure - Ingress protection (minimum) An example value being To BS EN 60529, IP21.
Enclosure - Material and construction - Type An example value being Welded carbon steel. Assemble to prevent distortion when the complete enclosure is lifted or transported.
Enclosure - Material and construction - Finish An example value being Epoxy powder coated.
Enclosure - Material and construction - Colour The Enclosure - Material and construction - Colour of the Central battery supply units.
Enclosure - Lockable access doors An example value being Required.
Enclosure - Cable entry An example value being Removable gland plates, for top entry cables.
Enclosure - Ventilation arrangement An example value being Forced ventilation fans during emergency mode.
Enclosure - Fan failure alarms An example value being Required.
Noise emission - Sound pressure level in normal mode (maximum) An example value being 60 dBA at 1 m.
Noise emission - Sound pressure level in battery mode (maximum) An example value being 65 dBA at 1 m.
System efficiency (minimum) An example value being 85%.
Battery - Type An example value being Lead-acid plante cells.
Battery - Labelling An example value being Indelibly mark with year of manufacture and installation.
Integral distribution board - Number of outgoing ways An example value being One.
Integral distribution board - Protection devices An example value being Double pole mcbs.
Integral distribution board - Protection devices - Rating An example value being 6 A.
Integral distribution board - Spare ways An example value being Fit with blanks.
Accessories An example value being Test button to simulate mains failure.
6

Provide the information specific to the installed deliverable that is required for operation and maintenance. Information covering the detailed maintenance should also be provided in the associated PDF manuals.

Name Definition
Asset type An indication of whether the object is fixed or movable.
Manufacturer Email address for the organisation responsible for supplying or manufacturing the object
ModelNumber The product, item or unit number assigned by the manufacturer of the object.
Warranty guarantor (parts) Email address for the organisation responsible for the parts warranty.
Warranty duration (parts) Duration of parts warranty.
Warranty guarantor (labour) Email address for the organisation responsible for the labour warranty.
Warranty duration (labour) Duration of labour warranty.
Warranty duration unit Duration of warranties (typical value is 'years').
Replacement cost An indicative cost for unit replacement.
Expected life The typical service life of the object.
Duration unit Duration of expected life (typical value is 'years')
Warranty description Description of the warranty content and any exclusions.
Nominal length Typically the larger or primary horizontal dimension.
Nominal width Nominal width of product, typically the characteristic or secondary horizontal or characteristic dimension.
Nominal height Typically the vertical or secondary characteristic dimension.
ModelReference The name of the object as used by the manufacturer.
Shape Characteristic shape of product.
Size Characteristic size of product.
Colour Characteristic or primary colour of product.
Finish Characteristic or primary finish of product.
Grade Standard grading which the product corresponds.
Material Characteristic or primary material of product.
Constituents Optional constituent features, parts or finishes.
Features Other important characteristics or features relevant to product specification.
Accessibility performance The accessibility issue(s) which the object satisfies.
Sustainability performance Description of the sustainability issue(s) which the object satisfies
Code performance The code compliance requirement(s) which the object satisfies
Serial number The serial number assigned to an occurrence of a product by the manufacturer (per instance).
Installation date The date that the manufactured item was installed (per instance).
Warranty start date The date on which the warranty commences.
Tag number The tag number assigned to an occurrence of a product by the occupier (per instance).
Bar code The identity of the bar code (or rfid) given to an occurrence of the product (per instance).
Asset identifier The identification assigned to an asset that enables its differentiation from other assets.