Provide enough information to allow the selection of the manufacturer product to meet requirements. This information may also be used to replace the installed product during the operation stage of the building's lifecycle. Information covering the execution of the deliverable should also be provided in the associated specification.
Name |
Definition |
|
Manufacturer |
An example value being As cubicle switchboard. |
|
Standards |
An example value being To BS EN 60947-1 and BS EN 60947-2. |
|
Third party certification |
An example value being ASTA Type test certification. |
|
Rated operational current (In) |
An example value being 630 A. |
|
Number of poles |
An example value being Three. |
|
Rated operational voltage (Ue) |
An example value being 690 V. a.c. |
|
Rated insulation voltage (Ui) |
The Rated insulation voltage (Ui) of the Air circuit breakers. |
|
Rated impulse withstand voltage (Uimp) |
An example value being 10 kV. |
|
Rated frequency |
An example value being 50 Hz. |
|
Rated ultimate short-circuit breaking capacity (Icu) |
An example value being 42 kA. |
|
Rated service short-circuit breaking capacity (Ics) |
An example value being 80% of Icu. |
|
Utilization category |
An example value being A. |
|
Protection - Type |
An example value being Microprocessor. |
|
Protection - Characteristics |
An example value being Interchangeable with fixed range of settings and adjustable parameters. |
|
Protection - Settings |
An example value being Earth leakage. |
|
Protection - Parameters |
An example value being Earth leakage sensitivity. |
|
Protection - Special features |
The Protection - Special features of the Air circuit breakers. |
|
Measurement |
An example value being Active, apparent and reactive powers. |
|
Visual indication |
An example value being LCD screen. |
|
Adjustment |
An example value being Dip switches. |
|
Communications - Remote monitoring |
An example value being Bluetooth™. |
|
Communications - Displays |
An example value being Bluetooth™. |
|
Charge mechanism |
An example value being Manual. |
|
Mechanical interlocking |
An example value being Captive key exchange type with square faced key and alphabetical or numerical coded operating face. |
|
Suitable for isolation |
An example value being Required. |
|
Provision for maintenance |
An example value being Maintainable. |
|
Method of installation |
An example value being Fixed. |
|
Ingress protection (minimum) |
An example value being To BS EN 60529, IP20. |
|
Connections - Position |
An example value being Front. |
|
Connections - Configuration |
An example value being Suitable for outgoing cable connection. |
|
Connections - Orientation |
An example value being Horizontal. |
|
Accessories |
An example value being Auxiliary contacts to BS EN 60947-5-1. |
|