Provide enough information to allow the selection of the manufacturer product to meet requirements. This information may also be used to replace the installed product during the operation stage of the building's lifecycle. Information covering the execution of the deliverable should also be provided in the associated specification.
Name |
Definition |
|
Manufacturer |
An example value being As distribution board. |
|
Standards |
An example value being To BS EN 60947-1 and BS EN 60947-2. |
|
Third party certification |
An example value being ASTA Type test certification
. |
|
Rated operational current (In) |
An example value being 16 A. |
|
Number of poles |
An example value being One. |
|
Rated operational voltage (Ue) |
An example value being 230 V a.c. |
|
Rated insulation voltage (Ui) |
An example value being 500 V a.c. |
|
Rated impulse withstand voltage (Uimp) |
An example value being 6 kV. |
|
Rated frequency |
An example value being 50 Hz. |
|
Rated ultimate short-circuit breaking capacity (Icu) |
An example value being 18 kA. |
|
Rated service short-circuit breaking capacity (Ics) |
An example value being 50% of Icu. |
|
Utilization category |
An example value being A. |
|
Protection - Type |
An example value being Electronic. |
|
Protection - Characteristics |
An example value being Interchangeable. |
|
Protection - Settings |
An example value being Adjustable thermal and fixed magnetic. |
|
Protection - Parameters |
An example value being Earth leakage sensitivity. |
|
Protection - Special features |
The Protection - Special features of the Moulded case circuit breakers. |
|
Measurement |
An example value being Active, apparent and reactive powers. |
|
Visual indication |
An example value being LCD screen. |
|
Adjustment |
An example value being Push buttons. |
|
Communications - Remote monitoring |
An example value being Ethernet. |
|
Communications - Displays |
An example value being Bluetoothâ„¢. |
|
Suitable for isolation |
An example value being Required. |
|
Operating handle - Manual |
An example value being Rotary direct. |
|
Operating handle - Electrical |
An example value being Remote controlled motor operation. |
|
Mechanical interlocking |
An example value being Captive key exchange type with square faced key and alphabetical or numerical coded operating face. |
|
Method of installation |
An example value being Fixed. |
|
Ingress protection (minimum) |
An example value being To BS EN 60529, IP30. |
|
Connections - Position |
An example value being Front. |
|
Connections - Configuration |
An example value being Screw-type. |
|
Accessories |
An example value being Auxiliary contacts to BS EN 60947-5-1. |
|