Provide enough information to allow the selection of the manufacturer product to meet requirements. This information may also be used to replace the installed product during the operation stage of the building's lifecycle. Information covering the execution of the deliverable should also be provided in the associated specification.
Name |
Definition |
|
Manufacturer |
The Manufacturer of the Surface luminaires. |
|
Standard |
An example value being To BS EN 60598-1 and. |
|
Third party certification |
An example value being ENEC
mark. |
|
Luminaire description |
The Luminaire description of the Surface luminaires. |
|
Classification - Electric shock |
An example value being To BS EN 60598-1, Class I. |
|
Classification - Ingress protection (minimum) |
An example value being To BS EN 60529, IP20. |
|
Classification - Suitability for direct mounting on normally flammable surfaces |
An example value being Suitable for direct mounting on normally flammable surfaces. |
|
Classification - Circumstances of use |
An example value being Normal. |
|
Rated maximum ambient temperature |
The Rated maximum ambient temperature of the Surface luminaires. |
|
Impact protection (minimum) |
An example value being IK02. |
|
Luminaire performance |
An example value being To BS EN 62722-1 and BS EN 13032-1. |
|
Control gear position |
An example value being Integral within luminaire. |
|
Supply circuit conductor connections |
An example value being Screw terminals. |
|
Internal fuse |
An example value being Required for incoming circuit phase connections. |
|
Nominal voltage |
An example value being 12 V a.c. |
|
Luminaire power factor |
An example value being Correct to minimum 0.9 lagging. |
|
LED luminaires - Performance standards |
An example value being To BS EN 62717 and BS EN 62722-2-1. |
|
LED luminaires - Safety standard |
An example value being To BS EN 62031. |
|
LED luminaires - Initial LED luminaire efficacy (minimum) |
The LED luminaires - Initial LED luminaire efficacy (minimum) of the Surface luminaires. |
|
LED luminaires - Wattage |
The LED luminaires - Wattage of the Surface luminaires. |
|
LED luminaires - Colour temperature |
An example value being 2700 K. |
|
LED luminaires - Colour rendering index (Ra) |
An example value being >90. |
|
LED luminaires - Beam angle |
An example value being 10°. |
|
LED luminaires - Useful life |
The LED luminaires - Useful life of the Surface luminaires. |
|
Non LED luminaires - Ballasts CELMA energy efficiency index (minimum) |
An example value being A1. |
|
Non LED luminaires - Number of lamps |
An example value being 1. |
|
Non LED luminaires - Lamp properties - Wattage |
The Non LED luminaires - Lamp properties - Wattage of the Surface luminaires. |
|
Non LED luminaires - Lamp properties - Colour temperature |
An example value being 2700 K. |
|
Non LED luminaires - Lamp properties - Colour rendering index (Ra) |
An example value being >90. |
|
Non LED luminaires - Lamp properties - Beam angle |
An example value being 10°. |
|
Non LED luminaires - Lamp properties - Initial lumens (minimum) |
The Non LED luminaires - Lamp properties - Initial lumens (minimum) of the Surface luminaires. |
|
Dimming protocol |
An example value being Analogue 0–10 V d.c. |
|
Emergency version - Standard |
An example value being To BS EN 60598-2-22. |
|
Emergency version - Classification - Type |
An example value being X. |
|
Emergency version - Classification - Mode of operation |
An example value being 0. |
|
Emergency version - Classification - Facilities |
An example value being A. |
|
Emergency version - Classification - Duration of emergency mode (minimum) |
An example value being 10. |
|
Integral sensors |
The Integral sensors of the Surface luminaires. |
|
Accessories |
An example value being Wire cage. |
|