Dry installation systems

A dry installation system typically comprises of items such as drive system oversizing factor, covers and ductwork.

Uniclass2015 - Ss_50_75_58_23 Dry installation systems
Reference Notes
NBS Code

50-55-45/120 Dry installation system

-
Download manufacturer object defintion template

Manufacturer Product Data template

Complete this electronic spreadsheet to ensure that your Dry installation systems product information meets the requirements of Level 2 BIM. This is important as it will enable your customers to select, specify and use your products within the BIM environment. Once you have completed this template you can host it on your own website or distribute it to your customers. Please note that we do not host completed product data templates within the BIM Toolkit.

2

Requirement

Graphical representation of element, dimensionally inaccurate.

Purpose of information

To provide a visual indication of proposals at a Concept stage identifying key requirements such as access and maintenance zones etc. Information to be suitable for zonal spatial coordination of primary systems / elements.

3

Requirement

Visual information to provide developed principles of the design to a greater level of detail. Developed coordination between all professions. Visual development showing coordination for general size and primary relationships between different elements of the construction. Can form a brief for a specialist sub-contractor or fabricator to progress with their technical design, fabrication and installation. This would be expected to include critical dimensional coordination, performance requirements and qualities of finish.

Purpose of information

To provide a visual representation of proposals, confirming brief for technical Design stage supporting full spatial coordination.

4

Requirement

Visual information to provide fixed principles of the design supporting procurement. Developed coordination between all professions. Visual representations showing coordination for general size and relationships between different elements of the construction. Graphical representation of system, dimensionally accurate indicating primary performance characteristics. Graphical information represented may alter dependant on visual information to be produced, eg: Scope of work drawings, setting out, floor loading etc Typical / Installation details separately produced linked to model element and adjacent constructions.

Purpose of information

To provide a visual representation of proposals at a Technical Design stage supporting full spatial coordination.

5

Requirement

Visual information to provide full information to support construction / installation. Developed coordination between all professions. Visual representations showing final coordination for size and relationships between different elements of the construction. Graphical representation of system, dimensionally accurate indicating primary performance characteristics and sufficient information to support installation. Typical / Installation details separately produced linked to model element and adjacent constructions.

Purpose of information

To be updated during the construction process to reflect the final design, and to provide a future reference to sit alongside the O&M Manuals.

Download manufacturer object defintion template

Manufacturer Product Data template

Complete this electronic spreadsheet to ensure that your Dry installation systems product information meets the requirements of Level 2 BIM. This is important as it will enable your customers to select, specify and use your products within the BIM environment. Once you have completed this template you can host it on your own website or distribute it to your customers. Please note that we do not host completed product data templates within the BIM Toolkit.

2

Provide an outline description of the deliverable.

Name Definition
Description A description of the type of object to detail any design intent.
3

Provide information relevant to the specific performance of the deliverable. Information to specify the completion (cleaning, testing, spares, training...) of the deliverable should also be provided in the associated specification.

Name Definition
Operating environment Environment, Hazardous area classification and EMC environment.
Source, volume and properties of odorous air Source, Volume and Minimum number of air changes per hour.
Process performance Process performance at outlet stack, Process performance at site boundary and Dispersion model used.
Odour emission stack performance Height (maximum) and Efflux velocity(maximum).
Durability Intended working life.
4

Provide information relevant to the specific child products of the deliverable to allow suitable products from manufacturers to be selected. Information covering the completion and execution of the deliverable and its child products should also be provided.

Name Definition
Standard The Standard of the Dry installation systems.
Drive system oversizing factor The Drive system oversizing factor of the Dry installation systems.
Covers The Covers of the Dry installation systems.
Ductwork The Ductwork of the Dry installation systems.
Odour emission stack The Odour emission stack of the Dry installation systems.
Standby fans The Standby fans of the Dry installation systems.
Control panel The Control panel of the Dry installation systems.
Dust filters The Dust filters of the Dry installation systems.
De-misters The De-misters of the Dry installation systems.
Media re-generation system The Media re-generation system of the Dry installation systems.
Inlet heater The Inlet heater of the Dry installation systems.
Bypass ductwork The Bypass ductwork of the Dry installation systems.
Number and configuration of treatment units and ancillary components The Number and configuration of treatment units and ancillary components of the Dry installation systems.
Treatment unit The Treatment unit of the Dry installation systems.
Treatment unit - Condensate to discharge to The Treatment unit - Condensate to discharge to of the Dry installation systems.
Treatment unit - Media sampling facility The Treatment unit - Media sampling facility of the Dry installation systems.
Treatment unit - Media analysis service The Treatment unit - Media analysis service of the Dry installation systems.
Media re-generation system - excess re-generating liquid discharge point The Media re-generation system - excess re-generating liquid discharge point of the Dry installation systems.
5

Provide information relevant to the specific child products of the deliverable to allow for purchasing. Information covering the completion and execution of the deliverable and its child products should also be provided.

Name Definition
Standard The Standard of the Dry installation systems.
Drive system oversizing factor The Drive system oversizing factor of the Dry installation systems.
Covers The Covers of the Dry installation systems.
Ductwork The Ductwork of the Dry installation systems.
Odour emission stack The Odour emission stack of the Dry installation systems.
Standby fans The Standby fans of the Dry installation systems.
Control panel The Control panel of the Dry installation systems.
Dust filters The Dust filters of the Dry installation systems.
De-misters The De-misters of the Dry installation systems.
Media re-generation system The Media re-generation system of the Dry installation systems.
Inlet heater The Inlet heater of the Dry installation systems.
Bypass ductwork The Bypass ductwork of the Dry installation systems.
Number and configuration of treatment units and ancillary components The Number and configuration of treatment units and ancillary components of the Dry installation systems.
Treatment unit The Treatment unit of the Dry installation systems.
Treatment unit - Condensate to discharge to The Treatment unit - Condensate to discharge to of the Dry installation systems.
Treatment unit - Media sampling facility The Treatment unit - Media sampling facility of the Dry installation systems.
Treatment unit - Media analysis service The Treatment unit - Media analysis service of the Dry installation systems.
Media re-generation system - excess re-generating liquid discharge point The Media re-generation system - excess re-generating liquid discharge point of the Dry installation systems.
6

Provide the information specific to the installed deliverable that is required for operation and maintenance. Information covering the detailed maintenance should also be provided in the associated PDF manuals.

Name Definition
Asset type An indication of whether the object is fixed or movable.
Manufacturer Email address for the organisation responsible for supplying or manufacturing the object
ModelNumber The product, item or unit number assigned by the manufacturer of the object.
Warranty guarantor (parts) Email address for the organisation responsible for the parts warranty.
Warranty duration (parts) Duration of parts warranty.
Warranty guarantor (labour) Email address for the organisation responsible for the labour warranty.
Warranty duration (labour) Duration of labour warranty.
Warranty duration unit Duration of warranties (typical value is 'years').
Replacement cost An indicative cost for unit replacement.
Expected life The typical service life of the object.
Duration unit Duration of expected life (typical value is 'years')
Warranty description Description of the warranty content and any exclusions.
Nominal length Typically the larger or primary horizontal dimension.
Nominal width Nominal width of product, typically the characteristic or secondary horizontal or characteristic dimension.
Nominal height Typically the vertical or secondary characteristic dimension.
ModelReference The name of the object as used by the manufacturer.
Shape Characteristic shape of product.
Size Characteristic size of product.
Colour Characteristic or primary colour of product.
Finish Characteristic or primary finish of product.
Grade Standard grading which the product corresponds.
Material Characteristic or primary material of product.
Constituents Optional constituent features, parts or finishes.
Features Other important characteristics or features relevant to product specification.
Accessibility performance The accessibility issue(s) which the object satisfies.
Sustainability performance Description of the sustainability issue(s) which the object satisfies
Code performance The code compliance requirement(s) which the object satisfies
Serial number The serial number assigned to an occurrence of a product by the manufacturer (per instance).
Installation date The date that the manufactured item was installed (per instance).
Warranty start date The date on which the warranty commences.
Tag number The tag number assigned to an occurrence of a product by the occupier (per instance).
Bar code The identity of the bar code (or rfid) given to an occurrence of the product (per instance).
Asset identifier The identification assigned to an asset that enables its differentiation from other assets.